 PT. ANEKA ELECTRINDO NUSANTARA Indonesia |
| Home |
| Company Info |
| Trade Offers |
| |
- Selling Offers(2)
|
| Products Catalog (53) |
| |
| - | |
Modul communications link BM 9100 AREVA | | - | |
ABB OVER CURRENT RELAY REJ 521 and REJ 525 | | - | |
Directional earth-fault relay SPAS 120 C ABB | | - | |
Relay SEPAM T20, S20, M20, B20 | | - | |
SEPAM 1000+ Relay Overcurrent and undercurrent protection relay MERLIN GERIN | | - | |
fuse 3, 3 Kv - 36 Kv | | - | |
BASLER Over current BE1-700C BASLER | | - | |
NEUTRAL GROUDING RESISTORS ( NGR) | | - | |
OVERCURRENT RELAYS MCGG, 22, 52, 62, 82 " ALSTOM" | | - | |
DIFFERENTIAL RELAY TRANSFORMER AND GENERATOR, OVER CURRENT SEPAM 1000+ series 80 MERLIN GERIN | | - | |
UNDER/ OVER VOLTAGE RELAY MVTU 11 | | - | |
EARTH FAULT RELAY MCAG " AREVA" / " ALSTOM" | | - | |
RELAY MICOM P122, P124, P127 " AREVA" | | - | |
DC UNDERVOLTAGE RELAY MODEL WUV 120 DC " WILMAR" | | - | |
Cable fault locator model 3300 | | - | |
Instantaneous Overcurrent Relays MCTI 19, 39, 40 ALSTOM | | - | |
PANEL CUBICAL / SWITCH GEAR MEDIUM & HIGH VOLTAGE | | - | |
Buchholz Relay COMEM type NF 80 | | - | |
CHECK SYNCHRONISM RELAY KAVS 100 / MAVS 01 " ALSTOM / AREVA" | | - | |
kwh ACTARIS SL 7000, ACE 100, ANALOG 3 Phase & ANALOG 1 phase | | - | |
Disturbance recorder TPE 2000 ALSTOM | | - | |
differential relay SEPAM 1000+ type 80 | | - | |
OVERCURRENT AND EARTH-FAULT PROTECTION RELAYSPAJ 140C | | - | |
FUSE 20 KV, 24Kv, 36Kv, 16Kv, 11Kv, 6Kv and Low Voltge NH FUSE., BUSSMANN, SIBA, ABB, SIEMEN, MERLIN GERIN, ETI, AREVA | | - | |
AUXILARY REALAY MVAA " AREVA / ALSTOM " | | - | |
METROSIL 600A/ S7/ P/ 6331, 600A/ S3/ I, 600A/ S1/ 1008 | | - | |
3M RESIN 3M | | - | |
ABB RTXP 8 COMBI TEST ( TEST SISTEM) | | - | |
OVER VOLTAGE RELAY SPAU 110C & SPAU 140C" ABB" | | - | |
AUTO RECLOSE RELAY MVTR 51 RELAY " ALSTOM" | | - | |
UNIVERSAL PROFESSIONAL MODEM AJ 2885 CXR ANDERSON JACOBSON | | - | |
TRANSFORMER DIFFERETIAL RELAY SEPAM 1000+ T 87 MERLIN GERIN | | - | |
ENTRELEC CTT and VTT terminal block, current voltage or polarity circuits | | - | |
GENERATOR DIFFERENTIAL RELAY SEPAM 1000+ TYPE G 88 MERLIN GERIN | | - | |
SEG RELAY MR13-IRSR and SEG RELAY MR13-IE | | - | |
SIEMENS RELAY 7SJ 6 XX | | - | |
TERMINATING AND JOINTING 1Kv - 33Kv Raychem, 3M, UEROMOLD | | - | |
PROTOCOL CONVERTER RELAY KITZ Relay AREVA | | - | |
AUTO RECLOSE RELAYL FAA 101 " AREVA" | | - | |
POWER SUPPLY IDEC | | - | |
Ampere & KiloAmpere SACI, Spain | | - | |
TEST BLOCK MMLG 01 " AREVA & ALSTOM" | | - | |
AUXILIARY RELAY HFA " GE" | | - | |
INVERTER OMRON, ABB, HITACHI, | | - | |
Motor protection relay SEPAM 1000+ M series | | - | |
ZIEHL Temperature monitoring MSF 220K T 221715 | | - | |
DISTANCE PROTECTION RELAY LFZR 111 / LFAA 101 " ALSTHOM" | | - | |
SURGE PROTECTION " DHEN" OBBO" ABB" MG. | | - | |
DISCT CONECTING SWITCH 20 Kv - 150 Kv | | - | |
CT ( Current transformer) 20Kv - 150Kv | | - | |
Scoth 23 3M | | - | |
KV Meter, Ampere meter . | | - | |
SUPERVISION RELAY MVAX 21 " ALSTOM" |
|
| Share your thoughts |
| |
- Write a review
- Recommend to your friends
|
| Contact Us |
| Language |
| | - English - Indonesia
|
| | |
|
| TEST BLOCK MMLG 01 " AREVA & ALSTOM" |
 (Product Photo) |
| | Features
• Test block can be mounted adjacent to
Midos modular relays and systems
• Test block obviates need to disturb
protective system wiring for testing
• Monitoring, isolation and secondary
injection testing are simplified and
quickly performed
Types Available
• MMLG 01
Standard test block
• MMLG 02
Special test block designed for use in
busbar protection schemes
• MMLG 03
Horizontal version of MMLG 01
• MMLG 04
Horizontal version of MMLG 02
• MMLB 01
Multi-finger test plug
• MMLB 02
Single-finger test plug
MMLG 01 and MMLB 01
terminals 13 and 14 must not be used
for CT connections since they may
present a safety hazard.
Application
Although designed within the Midos
range these test blocks offer facilities for
monitoring and secondary injection
testing any power system protection
scheme, when used with the multifingered
test plug type MMLB 01.
A single-finger test plug, type MMLB 02 is
also available for monitoring the current
flow in individual circuits which have
been routed through the test block.
Before use, the insulation of the
flying leads should be visually
checked for damage.
The continuity of the shorting plug/ wire
links, and the state of their insulation,
should be checked before insertion into
the MMLG 01 test block.
Description, Installation and
Use
The Safety Statements Publication R5948
should be read before installing or using
the test block ( MMLG) or test plug
( MMLB) .
Note. Terminals 13 and 14 have
short contact fingers which must
not be used for CT connections.
Refer to the Mechanical Details section
for a description of the test block
( MMLG) and test plug ( MMLB) . The
MMLG cover, when in place, provides
protection from electric shock hazard.
Care should be taken to ensure that
MMLG 01 covers are correctly
orientated when replaced.
The test block carries 14 circuits, each of
which is brought out to separate pairs of
terminals at the rear of the case.
Each circuit comprises a pair of internal
contacts which are normally sprung
together to complete the circuit link
through the block when the associated
protective equipment is in normal
service.
Access to these internal circuits for
testing purposes, can be gained by
removing the front cover. A metallic
probe secured to the inside face of the
MMLG 01 cover is automatically
withdrawn when the cover is removed,
so interrupting the circuit between
terminals 13 and 14. By routing the
main dc auxiliary supply to the
protection scheme or relay through this
circuit, removal of the test block cover
will thereby prevent inadvertent tripping
of the protection during the ensuing tests. | | |
|
| Origin: | France |
| Price: | negotiable |
| Quantity: | 20 UNIT |
| Pack. & Delivery: | kotak/box |
Your inquiry will be recorded in "Member Trade Mail". |
Recommend to your friends |
|
| Company Contact |
| Name: |
Mr. Dedi Satria [Director/CEO/General Manager] |
| E-mail: |
satria_aen@yahoo.co.id |
| Mobile Number: |
+628179978787 |
| Phone Number: |
+622170778109 |
| Fax Number: |
+62218470612 |
| Address: |
Komplek dosen IKIP Blok 2. No.43,Jati Bening Bekasi 17421, Jawa Barat Indonesia |
|