 PT. ANEKA ELECTRINDO NUSANTARA Indonesia |
| Home |
| Company Info |
| Trade Offers |
| |
- Selling Offers(1)
|
| Products Catalog (53) |
| |
| - | |
AUTO RECLOSE RELAY MVTR 51 RELAY " ALSTOM" | | - | |
NEUTRAL GROUDING RESISTORS ( NGR) | | - | |
fuse 3, 3 Kv - 36 Kv | | - | |
kwh ACTARIS SL 7000, ACE 100, ANALOG 3 Phase & ANALOG 1 phase | | - | |
Relay SEPAM T20, S20, M20, B20 | | - | |
SEPAM 1000+ Relay Overcurrent and undercurrent protection relay MERLIN GERIN | | - | |
GENERATOR DIFFERENTIAL RELAY SEPAM 1000+ TYPE G 88 MERLIN GERIN | | - | |
RELAY MICOM P124 " AREVA" | | - | |
OVER VOLTAGE RELAY SPAU 110C & SPAU 140C" ABB" | | - | |
3M RESIN 3M | | - | |
Disturbance recorder TPE 2000 ALSTOM | | - | |
UNDER/ OVER VOLTAGE RELAY MVTU 11 | | - | |
Modul communications link BM 9100 AREVA | | - | |
Instantaneous Overcurrent Relays MCTI 19, 39, 40 ALSTOM | | - | |
BASLER Over current BE1-700C BASLER | | - | |
SEG RELAY MR13-IRSR and SEG RELAY MR13-IE | | - | |
SIEMENS RELAY 7SJ 6 XX | | - | |
OVERCURRENT AND EARTH-FAULT PROTECTION RELAYSPAJ 140C | | - | |
DC UNDERVOLTAGE RELAY MODEL WUV 120 DC " WILMAR" | | - | |
DIFFERENTIAL RELAY TRANSFORMER AND GENERATOR, OVER CURRENT SEPAM 1000+ series 80 MERLIN GERIN | | - | |
TERMINATING AND JOINTING 1Kv - 33Kv Raychem, 3M, UEROMOLD | | - | |
PROTOCOL CONVERTER RELAY KITZ Relay AREVA | | - | |
AUTO RECLOSE RELAYL FAA 101 " AREVA" | | - | |
POWER SUPPLY IDEC | | - | |
OVERCURRENT RELAYS MCGG, 22, 52, 62, 82 " ALSTOM" | | - | |
PANEL CUBICAL / SWITCH GEAR MEDIUM & HIGH VOLTAGE | | - | |
ENTRELEC CTT and VTT terminal block, current voltage or polarity circuits | | - | |
Ampere & KiloAmpere SACI, Spain | | - | |
TEST BLOCK MMLG 01 " AREVA & ALSTOM" | | - | |
TRANSFORMER DIFFERETIAL RELAY SEPAM 1000+ T 87 MERLIN GERIN | | - | |
AUXILIARY RELAY HFA " GE" | | - | |
METROSIL 600A/ S7/ P/ 6331, 600A/ S3/ I, 600A/ S1/ 1008 | | - | |
INVERTER OMRON, ABB, HITACHI, | | - | |
Motor protection relay SEPAM 1000+ M series | | - | |
ZIEHL Temperature monitoring MSF 220K T 221715 | | - | |
UNIVERSAL PROFESSIONAL MODEM AJ 2885 CXR ANDERSON JACOBSON | | - | |
Buchholz Relay COMEM type NF 80 | | - | |
Directional earth-fault relay SPAS 120 C ABB | | - | |
CHECK SYNCHRONISM RELAY KAVS 100 / MAVS 01 " ALSTOM / AREVA" | | - | |
DISTANCE PROTECTION RELAY LFZR 111 / LFAA 101 " ALSTHOM" | | - | |
ABB RTXP 8 COMBI TEST ( TEST SISTEM) | | - | |
FUSE 20 KV, 24Kv, 36Kv, 16Kv, 11Kv, 6Kv and Low Voltge NH FUSE., BUSSMANN, SIBA, ABB, SIEMEN, MERLIN GERIN, ETI, AREVA | | - | |
SURGE PROTECTION " DHEN" OBBO" ABB" MG. | | - | |
ABB OVER CURRENT RELAY REJ 521 and REJ 525 | | - | |
DISCT CONECTING SWITCH 20 Kv - 150 Kv | | - | |
EARTH FAULT RELAY MCAG " AREVA" / " ALSTOM" | | - | |
CT ( Current transformer) 20Kv - 150Kv | | - | |
Scoth 23 3M | | - | |
AUXILARY REALAY MVAA " AREVA / ALSTOM " | | - | |
differential relay SEPAM 1000+ type 80 | | - | |
KV Meter, Ampere meter . | | - | |
SUPERVISION RELAY MVAX 21 " ALSTOM" | | - | |
Cable fault locator model 3300 |
|
| Share your thoughts |
| |
- Write a review
- Recommend to your friends
|
| Contact Us |
| Language |
| | - English - Indonesia
|
| | |
|
| ABB RTXP 8 COMBI TEST ( TEST SISTEM) |
 (Product Photo) |
| | Features • Fail-safe sequential disconnection of
current, voltage and trip circuits when the
test-plug handle is inserted.
• Latching feature when the test-plug handle
is withdrawn allowing the relay to stabilize
with service values before the trip circuits
are restored. This prevents inadvertent tripping.
• Complete isolation of secondary instrument
transformer circuits.
• Trip-block plug which isolates a trip circuit
without interrupting other circuits, allowing
the trip output to be monitored, and also
provides visual indication of an isolated trip
circuit.
• Block-plug handle which disconnects all
circuits routed through the test switch.
• Ammeter test-plug with local automatic
short-circuiting device in case of inadvertent
opening of a CT circuit.
• Auxiliary station power supply made
available for test equipment.
• Extension bases which facilitate
measurement and adjustment of plug-in
module circuits.
Application The COMBITEST system for testing of protection
relays is built up around the RTXP 8,
RTXP 18 or RTXP 24 test switches. The test
switch can also be used for other testing
needs not directly associated with relays,
such as for switchboards or voltmeters.
The test switch may be used where testing
would otherwise require disconnection of the
instrument transformer’ s secondary or control
wiring. It may also be used to advantage in
the testing of other complete relay systems,
even when each individual relay has its own
test switch.
When the test-plug handle is inserted into the
test switch, preparations for testing are automatically
carried out in the proper sequence,
i.e. blocking of tripping circuits, short-circuiting
of CT’ s, opening of voltage circuits, making
relay terminals available for secondary
injection.
The test-plug handle may be connected to any
type of test equipment or instrument. When a
number of protection relays of the same type
are tested, the test-plug handle need to be
moved only from the test switch of one relay
to the test switch of the other, without altering
previously made connections. If different
types of relays are to be tested, it is a simple
matter to change the connections on the testplug
handle and the relay testing set. | | |
|
| Origin: | Sweden |
| Price: | negotiable |
| Payment Method: | Cashier Order |
| Quantity: | 1 SET |
| Pack. & Delivery: | NO PAKING |
Your inquiry will be recorded in "Member Trade Mail". |
Recommend to your friends |
|
| Company Contact |
| Name: |
Mr. Dedi Satria [Director/CEO/General Manager] |
| E-mail: |
dedi_spm@yahoo.com |
| Mobile Number: |
+628179978787 |
| Phone Number: |
+622170778109 |
| Fax Number: |
+62218470612 |
| Address: |
Komplek dosen IKIP Blok 2. No.43,Jati Bening Bekasi 17421, Jawa Barat Indonesia |
|