 PT. ANEKA ELECTRINDO NUSANTARA Indonesia |
| Home |
| Company Info |
| Trade Offers |
| |
- Selling Offers(2)
|
| Products Catalog (53) |
| |
| - | |
Modul communications link BM 9100 AREVA | | - | |
ABB OVER CURRENT RELAY REJ 521 and REJ 525 | | - | |
Directional earth-fault relay SPAS 120 C ABB | | - | |
Relay SEPAM T20, S20, M20, B20 | | - | |
SEPAM 1000+ Relay Overcurrent and undercurrent protection relay MERLIN GERIN | | - | |
fuse 3, 3 Kv - 36 Kv | | - | |
BASLER Over current BE1-700C BASLER | | - | |
NEUTRAL GROUDING RESISTORS ( NGR) | | - | |
OVERCURRENT RELAYS MCGG, 22, 52, 62, 82 " ALSTOM" | | - | |
DIFFERENTIAL RELAY TRANSFORMER AND GENERATOR, OVER CURRENT SEPAM 1000+ series 80 MERLIN GERIN | | - | |
UNDER/ OVER VOLTAGE RELAY MVTU 11 | | - | |
EARTH FAULT RELAY MCAG " AREVA" / " ALSTOM" | | - | |
RELAY MICOM P122, P124, P127 " AREVA" | | - | |
DC UNDERVOLTAGE RELAY MODEL WUV 120 DC " WILMAR" | | - | |
Cable fault locator model 3300 | | - | |
Instantaneous Overcurrent Relays MCTI 19, 39, 40 ALSTOM | | - | |
PANEL CUBICAL / SWITCH GEAR MEDIUM & HIGH VOLTAGE | | - | |
Buchholz Relay COMEM type NF 80 | | - | |
CHECK SYNCHRONISM RELAY KAVS 100 / MAVS 01 " ALSTOM / AREVA" | | - | |
kwh ACTARIS SL 7000, ACE 100, ANALOG 3 Phase & ANALOG 1 phase | | - | |
Disturbance recorder TPE 2000 ALSTOM | | - | |
differential relay SEPAM 1000+ type 80 | | - | |
OVERCURRENT AND EARTH-FAULT PROTECTION RELAYSPAJ 140C | | - | |
FUSE 20 KV, 24Kv, 36Kv, 16Kv, 11Kv, 6Kv and Low Voltge NH FUSE., BUSSMANN, SIBA, ABB, SIEMEN, MERLIN GERIN, ETI, AREVA | | - | |
AUXILARY REALAY MVAA " AREVA / ALSTOM " | | - | |
METROSIL 600A/ S7/ P/ 6331, 600A/ S3/ I, 600A/ S1/ 1008 | | - | |
3M RESIN 3M | | - | |
ABB RTXP 8 COMBI TEST ( TEST SISTEM) | | - | |
OVER VOLTAGE RELAY SPAU 110C & SPAU 140C" ABB" | | - | |
AUTO RECLOSE RELAY MVTR 51 RELAY " ALSTOM" | | - | |
UNIVERSAL PROFESSIONAL MODEM AJ 2885 CXR ANDERSON JACOBSON | | - | |
TRANSFORMER DIFFERETIAL RELAY SEPAM 1000+ T 87 MERLIN GERIN | | - | |
ENTRELEC CTT and VTT terminal block, current voltage or polarity circuits | | - | |
GENERATOR DIFFERENTIAL RELAY SEPAM 1000+ TYPE G 88 MERLIN GERIN | | - | |
SEG RELAY MR13-IRSR and SEG RELAY MR13-IE | | - | |
SIEMENS RELAY 7SJ 6 XX | | - | |
TERMINATING AND JOINTING 1Kv - 33Kv Raychem, 3M, UEROMOLD | | - | |
PROTOCOL CONVERTER RELAY KITZ Relay AREVA | | - | |
AUTO RECLOSE RELAYL FAA 101 " AREVA" | | - | |
POWER SUPPLY IDEC | | - | |
Ampere & KiloAmpere SACI, Spain | | - | |
TEST BLOCK MMLG 01 " AREVA & ALSTOM" | | - | |
AUXILIARY RELAY HFA " GE" | | - | |
INVERTER OMRON, ABB, HITACHI, | | - | |
Motor protection relay SEPAM 1000+ M series | | - | |
ZIEHL Temperature monitoring MSF 220K T 221715 | | - | |
DISTANCE PROTECTION RELAY LFZR 111 / LFAA 101 " ALSTHOM" | | - | |
SURGE PROTECTION " DHEN" OBBO" ABB" MG. | | - | |
DISCT CONECTING SWITCH 20 Kv - 150 Kv | | - | |
CT ( Current transformer) 20Kv - 150Kv | | - | |
Scoth 23 3M | | - | |
KV Meter, Ampere meter . | | - | |
SUPERVISION RELAY MVAX 21 " ALSTOM" |
|
| Share your thoughts |
| |
- Write a review
- Recommend to your friends
|
| Contact Us |
| Language |
| | - English - Indonesia
|
| | |
|
| differential relay SEPAM 1000+ type 80 |
 (Product Photo) |
| | Electrical Network Management
Medium and low voltage
Protection unit
Sepam 1000+ series 40 is a family of digital units
used for current and voltage protection
in any medium or low voltage distribution system.
Sepam 1000+ series 40
Sepam 1000+ and
its optional modules:
Conformity standards
IEC 60255 - Protection relays
IEC 60529 - Degree of protection IP52 on front panel
IEC 60068 - Operating temperature -25° C to + 70° C
Auxiliary power supply
24-250Vdc and 110-240Vac
Base unit dimensions
Overall dimensions ( w x h x d) 176 x 222 x 130 mm
3
5
6 2
1
4
7
1 Base unit, with various
User/ Machine Interface levels ( UMI) :
c standard UMI,
c advanced UMI with graphic LCD screen.
2 Remote advanced UMI.
3 Digital inputs/ outputs extension module
( 4I/ 4O or 10I/ 4O) .
4 Connection module for Modbus
communication network.
5 Temperature acquisition module for
transformers or motors.
6 Analogue output module.
7 Software tools:
c Sepam1000+ parameters and protection
settings, control logic customisation,
c disturbance recording display.
We do more with electricity.
LAUNCHLAUNCH
DOCUMENTDOCUMENT
AdvancedAdvanced
informationinfor mation
to confirmedto be confirmed
Schneider Electric
Industries SA
ART. 07900
Postal address
F-38050 Grenoble cedex 9
France
tel: 33 ( 0) 4 76 57 60 60
fax: 33 ( 0) 4 76 60 58 82
http: / / www.schneider-electric.com
this document has been
printed on ecological
paper.
As standards and equipment change from time to time,
always ask for confirmation of the information given in this
document.
Publication: Schneider Electric Industries SA
Design: communication Schneider Electric MT
Printing: Imprimerie des Deux-Ponts
Sepam 1000+ series 40 rear face:
c 1 Base unit
v A Main connector
v B Input current connector
v C Modbus communication port
v D Link to the optional modules
v E Input voltage connector
c 2 Optional digital inputs/ outputs module
c S40, S41, S42: substation incomers
and feeders protection
c T40, T42: transformer protection
c M41: motor protection
Sepam 1000+ series 40, 6 current and voltage applications:
L1
L2
L3
O2
O3
O1
O4
+ / ~
- / ~
Modbus
communication
port
Link to
the optional
modules
Sepam 1000+ series 40 connection scheme
01/ 01
PCRED301002EN
: available 2nd half of 2001
: available 1nd half of 2002
protections code ANSI S40 S41 S42 T40 T42 M41
phase overcurrent 50/ 51 4 4 4 4 4 4
earth fault 50N/ 51N 4 4 4 4 4 4
50G/ 51G
breaker failure 50BF 1 1 1 1 1 1
unbalance/ negative sequence 46 2 2 2 2 2 2
directional phase overcurrent 67 2 2
directional earth fault 67N/ 67NC 2 2 2 2
real overpower 32P 1 1 1
thermal overload 49 RMS 2 2 2
phase undercurrent 37 1
excessive starting time, locked rotor 48/ 51LR 1
starts per hour 66 1
positive sequence undervoltage 27D 2
remanent undervoltage 27R 1
undervoltage 27 2 2 2
overvoltage 59 2 2 2 2 2 2
neutral voltage displacement 59N 2 2 2
negative sequence overvoltage 47 1 1 1 1 1 1
underfrequency 81L 4 4 4 4 4 4
overfrequency 81H 2 2 2 2 2 2
recloser 79 v v v
thermostat / Buchholz v v
temperature monitoring 38/ 49T v v v
( 8 or 16 RTDs, 2 set points per RTD)
metering
RMS phase current I1, I2, I3, residual current I0 c c c c c c
average current I1, I2, I3 c c c c c c
peak demand current IM1, IM2, IM3
line voltage U21, U32, U13, c c c c c c
phase-to-neutral voltage V1, V2, V3
residual voltage V0
positive sequence voltage/ c c c c c c
rotation direction
negative sequence voltage c c c c c c
frequency c c c c c c
real/ reactive power P, Q c c c c c c
peak demand real/ reactive power PM, QM
power factor
accumulated real/ reactive energy ( + Wh, + VARh) c c c c c c
temperature measurement v v v
network and machine diagnosis
tripping current TripI1, TripI2, TripI3, TripI0 c c c c c c
tripping context c c c c c c
unbalance ratio/ negative sequence current c c c c c c
phase shift Õ 0, Õ 1, Õ 2, Õ 3 c c c c c c
disturbance recording c c c c c c
thermal capacity used c c c
remaining operating time c c c
before overload tripping
waiting time after c c c
overload tripping
running hours counter/ operating time c c c
starting current and time c
start inhibit time delay, c
number of starts before inhibition
switchgear diagnosis
cumulative breaking current2 c c c c c c
trip circuit supervision v v v v v v
number of operations, operating time, v v v v v v
charging time
CT/ VT supervision c c c c c c
self-diagnosis
watchdog c c c c c c
output relay test v v v v v v
control and monitoring
circuit breaker/ contactor control c c c c c c
logic discrimination v v v v v v
switching of group of settings c c c c c c
4 addressable logic outputs c c c c c c
logical equation editor c c c c c c
c standard, v according to parameter settings and optional modules. | | |
|
| Origin: | France |
| Price: | negotiable |
| Quantity: | 5 UNIT |
| Pack. & Delivery: | CARTON BOX |
Your inquiry will be recorded in "Member Trade Mail". |
Recommend to your friends |
|
| Company Contact |
| Name: |
Mr. Dedi Satria [Director/CEO/General Manager] |
| E-mail: |
satria_aen@yahoo.co.id |
| Mobile Number: |
+628179978787 |
| Phone Number: |
+622170778109 |
| Fax Number: |
+62218470612 |
| Address: |
Komplek dosen IKIP Blok 2. No.43,Jati Bening Bekasi 17421, Jawa Barat Indonesia |
|